Quick™ Metal Antibody Labeling Kit (VS-0824-FY129)
CAT#: VS-0824-FY129
The quick metal antibody labeling kit is a convenient and quick procedure for labeling proteins, peptides, and other biomolecules with metal. The product requires minimal hands-on time and produces conjugates ready for use in less than twenty minutes. The kit is suitable for labeling purified antibodies in appropriate buffers and at suitable concentrations. For incompatible buffers and low antibody concentrations, we offers a rapid conjugation service.
Sub Cat | Fluorescent Dye Name | Product Name | |
VS-0824-FY56 | 147Sm | Quick™ 147Sm Metal Antibody Labeling Kit | |
VS-0824-FY57 | 141Pr | Quick™ 141Pr Metal Antibody Labeling Kit | |
VS-0824-FY58 | 142Nd | Quick™ 142Nd Metal Antibody Labeling Kit | |
VS-0824-FY59 | 143Nd | Quick™ 143Nd Metal Antibody Labeling Kit | |
VS-0824-FY60 | 144Nd | Quick™ 144Nd Metal Antibody Labeling Kit | |
VS-0824-FY61 | 146Nd | Quick™ 146Nd Metal Antibody Labeling Kit | |
VS-0824-FY62 | 151Eu | Quick™ 151Eu Metal Antibody Labeling Kit | |
VS-0824-FY63 | 153Eu | Quick™ 153Eu Metal Antibody Labeling Kit | |
VS-0824-FY64 | 154Sm | Quick™ 154Sm Metal Antibody Labeling Kit | |
VS-0824-FY65 | 160Gd | Quick™ 160Gd Metal Antibody Labeling Kit | |
VS-0824-FY66 | 164Dy | Quick™ 164Dy Metal Antibody Labeling Kit | |
VS-0824-FY67 | 165Ho | Quick™ 165Ho Metal Antibody Labeling Kit | |
VS-0824-FY68 | 169Tm | Quick™ 169Tm Metal Antibody Labeling Kit | |
VS-0824-FY69 | 175Lu | Quick™ 175Lu Metal Antibody Labeling Kit | |
VS-0824-FY70 | 148Nd | Quick™ 148Nd Metal Antibody Labeling Kit | |
VS-0824-FY71 | 149Sm | Quick™ 149Sm Metal Antibody Labeling Kit | |
VS-0824-FY72 | 152Sm | Quick™ 152Sm Metal Antibody Labeling Kit | |
VS-0824-FY73 | 156Gd | Quick™ 156Gd Metal Antibody Labeling Kit | |
VS-0824-FY74 | 158Gd | Quick™ 158Gd Metal Antibody Labeling Kit | |
VS-0824-FY75 | 162Dy | Quick™ 162Dy Metal Antibody Labeling Kit | |
VS-0824-FY76 | 166Er | Quick™ 166Er Metal Antibody Labeling Kit | |
VS-0824-FY77 | 167Er | Quick™ 167Er Metal Antibody Labeling Kit | |
VS-0824-FY78 | 168Er | Quick™ 168Er Metal Antibody Labeling Kit | |
VS-0824-FY79 | 170Er | Quick™ 170Er Metal Antibody Labeling Kit | |
VS-0824-FY80 | 171Yb | Quick™ 171Yb Metal Antibody Labeling Kit | |
VS-0824-FY81 | 172Yb | Quick™ 172Yb Metal Antibody Labeling Kit | |
VS-0824-FY82 | 174Yb | Quick™ 174Yb Metal Antibody Labeling Kit | |
VS-0824-FY83 | 159Tb | Quick™ 159Tb Metal Antibody Labeling Kit | |
VS-0824-FY84 | 176Yb | Quick™ 176Yb Metal Antibody Labeling Kit |
Specifications
- Fluorescent Dye Name
- Metal
- Composition
- Metal mix (Lyophilized)
Modifier reagent
Quencher reagent
- Procedure Steps
- Allow all the reagents to come to room temperature.
Dilute the antibody to a concentration of 1 mg/mL (refer to buffer compatibility table) and add 1 μL of 147 Sm Modifier reagent for every 10 μL of antibody to be conjugated. Use 11 μL or 110 μL of the antibody mix for a 10 μg or 100 μg vial, respectively.
Open the vial and pipette 11 μL or 110 μL of the antibody mixture directly onto the lyophilized material. Gently resuspend the solution by withdrawing and dispensing the liquid until it becomes clear.
Place the cap back on the vial and let the conjugation occur at room temperature (20-25°C) for 1 hour. After the conjugation time, add 1 μL or 10 μL (10 μg or 100 μg vial respectively) of 147Sm quencher Reagent. The conjugates will be ready for use after 15 minutes and purification is not necessary.
Note: It is recommended to store the conjugates at 4°C. For longer storage, the conjugate can be stored at -20°C with a cryoprotectant such as 50% glycerol.
Please refer to the COA of the shipped product.
- Product Precautions
- Before conjugating antibodies, it is important to ensure that the purified antibody is in a suitable buffer, such as 10-50 mM amine-free buffer (e.g. MES, MOPS, HEPES, PBS) with a pH range of 6.5 to 8.5. Borate buffer can also be used.
It is recommended to avoid using buffer components that are nucleophilic, as they may react with the chemicals in the antibody Labeling Kit. Compounds containing primary amines (e.g. amino acids, ethanolamine, Tris) and thiols (e.g. mercaptoethanol, DTT) should be avoided. Thimerosal should also be avoided.
Common non-buffering salts, chelating agents, sugars, BSA (< 0.1%), glycerol (< 50%), Tris (< 50 mM), and gelatin (< 0.1%) have little to no effect on conjugation efficiency and can be used without concern.
This product is intended for research purposes only and is not intended for use in human, therapeutic, or diagnostic applications.
- Kit Storage
- Upon receipt, store the kit immediately in the dark at -20°C and check individual storage requirements for each component. If the components have not been reconstituted, the kit can be stored for up to 1 year from receipt.
- Conjugate Storage
- It is advisable to store any conjugate at 4°C. For extended storage, the conjugate can be kept at -20°C with a cryoprotectant such as 50% glycerol.
- Assay Platform
- These metals are typically detected through Atomic Absorption Spectroscopy (AAS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The specific method used depends on the experimental setup of the researchers.
- Sample Type
- The antibody should be purified, in a suitable buffer for conjugation, and at the correct concentration. If you need more information on how to label the antibody, please reach out to us.
- Reactive Species
- The reactive species of the kit depends on the research application of the antibody.
- Fluorescent Dye Introduction
- These metals are all rare earth elements that have unique properties and are used in various industrial applications. These metals are often used in the production of electronics, magnets, and nuclear energy. Each of these metals has unique properties that make them valuable in a variety of applications. From powering green technologies to improving the efficiency of electronic devices, these rare earth elements play a crucial role in modern industry.
- Alter Name
- Quick™ 147Sm Metal Antibody Labeling Kit; Quick™ 141Pr Metal Antibody Labeling Kit; Quick™ 142Nd Metal Antibody Labeling Kit; Quick™ 143Nd Metal Antibody Labeling Kit; Quick™ 144Nd Metal Antibody Labeling Kit; Quick™ 146Nd Metal Antibody Labeling Kit; Quick™ 151Eu Metal Antibody Labeling Kit; Quick™ 153Eu Metal Antibody Labeling Kit; Quick™ 154Sm Metal Antibody Labeling Kit; Quick™ 160 gd Metal Antibody Labeling Kit; Quick™ 164Dy Metal Antibody Labeling Kit; Quick™ 165Ho Metal Antibody Labeling Kit; Quick™ 169™ Metal Antibody Labeling Kit; Quick™ 175Lu Metal Antibody Labeling Kit; Quick™ 148Nd Metal Antibody Labeling Kit; Quick™ 149Sm Metal Antibody Labeling Kit; Quick™ 152Sm Metal Antibody Labeling Kit; Quick™ 156Gd Metal Antibody Labeling Kit; Quick™ 158Gd Metal Antibody Labeling Kit; Quick™ 162Dy Metal Antibody Labeling Kit; Quick™ 166Er Metal Antibody Labeling Kit; Quick™ 167Er Metal Antibody Labeling Kit; Quick™ 168Er Metal Antibody Labeling Kit; Quick™ 170Er Metal Antibody Labeling Kit; Quick™ 171Yb Metal Antibody Labeling Kit; Quick™ 172Yb Metal Antibody Labeling Kit; Quick™ 174Yb Metal Antibody Labeling Kit; Quick™ 159Tb Metal Antibody Labeling Kit; Quick™ 176Yb Metal Antibody Labeling Kit
Customer Review
There are currently no Customer reviews or questions for VS-0824-FY129. Click the button above to contact us or submit your feedback about this product.
Submit Your Publication
Published with our product? Submit your paper and receive a 10% discount on your next order! Share your research to earn exclusive rewards.
Downloadable Resources
Download resources about recombinant antibody development and antibody engineering to boost your research.
Datasheet
MSDS
COA
Certificate of Analysis LookupTo download a Certificate of Analysis, please enter a lot number in the search box below. Note: Certificate of Analysis not available for kit components.
Related Products
- CAT
- Product Name
See other products for "Metal"
Select a product category from the dropdown menu below to view related products.
CAT | Product Name | Application | Type |
---|---|---|---|
VS-0824-FY175 | Quick™ Metal Antibody Labeling Kit (VS-0824-FY175) | Immunohistochemistry |
Popular Products
Application: FC, IP, ELISA, Neut, FuncS, IF, IHC
Application: ELISA, IP, FC, FuncS, Neut, IF, ICC
Application: FuncS, IF, Neut, ELISA, FC, IP, ICC
Application: WB, ELISA, FC, IP, FuncS, IF, Neut
Application: FuncS, IF, Neut, ELISA, FC, IP, IHC
Application: FC, IB, Block, Inhib, FuncS, ELISA, FACS, IP, IF
Application: ELISA, IHC, FC, IP, IF, FuncS
Application: ELISA, IHC, FC, IP, IF, Inhib
Application: ELISA, WB
Application: ELISA, FuncS, Neut, IF, WB, EM, Inhib, IHC
Application: ELISA, Block, WB, FC, IP
For research use only. Not intended for any clinical use. No products from Creative Biolabs may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative Biolabs.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.