Quick™ Metal Antibody Labeling Kit (VS-0824-FY129)

CAT#: VS-0824-FY129

The quick metal antibody labeling kit is a convenient and quick procedure for labeling proteins, peptides, and other biomolecules with metal. The product requires minimal hands-on time and produces conjugates ready for use in less than twenty minutes. The kit is suitable for labeling purified antibodies in appropriate buffers and at suitable concentrations. For incompatible buffers and low antibody concentrations, we offers a rapid conjugation service.

Sub Cat Fluorescent Dye Name Product Name  
VS-0824-FY56 147Sm Quick™ 147Sm Metal Antibody Labeling Kit
VS-0824-FY57 141Pr Quick™ 141Pr Metal Antibody Labeling Kit
VS-0824-FY58 142Nd Quick™ 142Nd Metal Antibody Labeling Kit
VS-0824-FY59 143Nd Quick™ 143Nd Metal Antibody Labeling Kit
VS-0824-FY60 144Nd Quick™ 144Nd Metal Antibody Labeling Kit
VS-0824-FY61 146Nd Quick™ 146Nd Metal Antibody Labeling Kit
VS-0824-FY62 151Eu Quick™ 151Eu Metal Antibody Labeling Kit
VS-0824-FY63 153Eu Quick™ 153Eu Metal Antibody Labeling Kit
VS-0824-FY64 154Sm Quick™ 154Sm Metal Antibody Labeling Kit
VS-0824-FY65 160Gd Quick™ 160Gd Metal Antibody Labeling Kit
VS-0824-FY66 164Dy Quick™ 164Dy Metal Antibody Labeling Kit
VS-0824-FY67 165Ho Quick™ 165Ho Metal Antibody Labeling Kit
VS-0824-FY68 169Tm Quick™ 169Tm Metal Antibody Labeling Kit
VS-0824-FY69 175Lu Quick™ 175Lu Metal Antibody Labeling Kit
VS-0824-FY70 148Nd Quick™ 148Nd Metal Antibody Labeling Kit
VS-0824-FY71 149Sm Quick™ 149Sm Metal Antibody Labeling Kit
VS-0824-FY72 152Sm Quick™ 152Sm Metal Antibody Labeling Kit
VS-0824-FY73 156Gd Quick™ 156Gd Metal Antibody Labeling Kit
VS-0824-FY74 158Gd Quick™ 158Gd Metal Antibody Labeling Kit
VS-0824-FY75 162Dy Quick™ 162Dy Metal Antibody Labeling Kit
VS-0824-FY76 166Er Quick™ 166Er Metal Antibody Labeling Kit
VS-0824-FY77 167Er Quick™ 167Er Metal Antibody Labeling Kit
VS-0824-FY78 168Er Quick™ 168Er Metal Antibody Labeling Kit
VS-0824-FY79 170Er Quick™ 170Er Metal Antibody Labeling Kit
VS-0824-FY80 171Yb Quick™ 171Yb Metal Antibody Labeling Kit
VS-0824-FY81 172Yb Quick™ 172Yb Metal Antibody Labeling Kit
VS-0824-FY82 174Yb Quick™ 174Yb Metal Antibody Labeling Kit
VS-0824-FY83 159Tb Quick™ 159Tb Metal Antibody Labeling Kit
VS-0824-FY84 176Yb Quick™ 176Yb Metal Antibody Labeling Kit
More Infomation

Specifications

  • Fluorescent Dye Name
  • Metal
  • Composition
  • Metal mix (Lyophilized)
    Modifier reagent
    Quencher reagent
  • Procedure Steps
  • Allow all the reagents to come to room temperature.
    Dilute the antibody to a concentration of 1 mg/mL (refer to buffer compatibility table) and add 1 μL of 147 Sm Modifier reagent for every 10 μL of antibody to be conjugated. Use 11 μL or 110 μL of the antibody mix for a 10 μg or 100 μg vial, respectively.
    Open the vial and pipette 11 μL or 110 μL of the antibody mixture directly onto the lyophilized material. Gently resuspend the solution by withdrawing and dispensing the liquid until it becomes clear.
    Place the cap back on the vial and let the conjugation occur at room temperature (20-25°C) for 1 hour. After the conjugation time, add 1 μL or 10 μL (10 μg or 100 μg vial respectively) of 147Sm quencher Reagent. The conjugates will be ready for use after 15 minutes and purification is not necessary.
    Note: It is recommended to store the conjugates at 4°C. For longer storage, the conjugate can be stored at -20°C with a cryoprotectant such as 50% glycerol.
    Please refer to the COA of the shipped product.
  • Product Precautions
  • Before conjugating antibodies, it is important to ensure that the purified antibody is in a suitable buffer, such as 10-50 mM amine-free buffer (e.g. MES, MOPS, HEPES, PBS) with a pH range of 6.5 to 8.5. Borate buffer can also be used.
    It is recommended to avoid using buffer components that are nucleophilic, as they may react with the chemicals in the antibody Labeling Kit. Compounds containing primary amines (e.g. amino acids, ethanolamine, Tris) and thiols (e.g. mercaptoethanol, DTT) should be avoided. Thimerosal should also be avoided.
    Common non-buffering salts, chelating agents, sugars, BSA (< 0.1%), glycerol (< 50%), Tris (< 50 mM), and gelatin (< 0.1%) have little to no effect on conjugation efficiency and can be used without concern.
    This product is intended for research purposes only and is not intended for use in human, therapeutic, or diagnostic applications.
  • Kit Storage
  • Upon receipt, store the kit immediately in the dark at -20°C and check individual storage requirements for each component. If the components have not been reconstituted, the kit can be stored for up to 1 year from receipt.
  • Conjugate Storage
  • It is advisable to store any conjugate at 4°C. For extended storage, the conjugate can be kept at -20°C with a cryoprotectant such as 50% glycerol.
  • Assay Platform
  • These metals are typically detected through Atomic Absorption Spectroscopy (AAS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The specific method used depends on the experimental setup of the researchers.
  • Sample Type
  • The antibody should be purified, in a suitable buffer for conjugation, and at the correct concentration. If you need more information on how to label the antibody, please reach out to us.
  • Reactive Species
  • The reactive species of the kit depends on the research application of the antibody.
  • Fluorescent Dye Introduction
  • These metals are all rare earth elements that have unique properties and are used in various industrial applications. These metals are often used in the production of electronics, magnets, and nuclear energy. Each of these metals has unique properties that make them valuable in a variety of applications. From powering green technologies to improving the efficiency of electronic devices, these rare earth elements play a crucial role in modern industry.
  • Alter Name
  • Quick™ 147Sm Metal Antibody Labeling Kit; Quick™ 141Pr Metal Antibody Labeling Kit; Quick™ 142Nd Metal Antibody Labeling Kit; Quick™ 143Nd Metal Antibody Labeling Kit; Quick™ 144Nd Metal Antibody Labeling Kit; Quick™ 146Nd Metal Antibody Labeling Kit; Quick™ 151Eu Metal Antibody Labeling Kit; Quick™ 153Eu Metal Antibody Labeling Kit; Quick™ 154Sm Metal Antibody Labeling Kit; Quick™ 160 gd Metal Antibody Labeling Kit; Quick™ 164Dy Metal Antibody Labeling Kit; Quick™ 165Ho Metal Antibody Labeling Kit; Quick™ 169™ Metal Antibody Labeling Kit; Quick™ 175Lu Metal Antibody Labeling Kit; Quick™ 148Nd Metal Antibody Labeling Kit; Quick™ 149Sm Metal Antibody Labeling Kit; Quick™ 152Sm Metal Antibody Labeling Kit; Quick™ 156Gd Metal Antibody Labeling Kit; Quick™ 158Gd Metal Antibody Labeling Kit; Quick™ 162Dy Metal Antibody Labeling Kit; Quick™ 166Er Metal Antibody Labeling Kit; Quick™ 167Er Metal Antibody Labeling Kit; Quick™ 168Er Metal Antibody Labeling Kit; Quick™ 170Er Metal Antibody Labeling Kit; Quick™ 171Yb Metal Antibody Labeling Kit; Quick™ 172Yb Metal Antibody Labeling Kit; Quick™ 174Yb Metal Antibody Labeling Kit; Quick™ 159Tb Metal Antibody Labeling Kit; Quick™ 176Yb Metal Antibody Labeling Kit
REVIEWS AND Q&AS CITATIONS RESOURCES DOWNLOADS RELATED PRODUCTS
Inquiry
Navs

Customer Review

Submit a review or a question

There are currently no Customer reviews or questions for VS-0824-FY129. Click the button above to contact us or submit your feedback about this product.

Submit Your Publication

Published with our product? Submit your paper and receive a 10% discount on your next order! Share your research to earn exclusive rewards.

Article title:
DOI/PubMed URL:
Email:
Name:

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Downloadable Resources

Download resources about recombinant antibody development and antibody engineering to boost your research.

Datasheet

MSDS

COA

Certificate of Analysis Lookup

To download a Certificate of Analysis, please enter a lot number in the search box below. Note: Certificate of Analysis not available for kit components.

Lot Number:

Related Products

See other products for "Metal"

Select a product category from the dropdown menu below to view related products.

CAT Product Name Application Type
VS-0824-FY175 Quick™ Metal Antibody Labeling Kit (VS-0824-FY175) Immunohistochemistry

For research use only. Not intended for any clinical use. No products from Creative Biolabs may be resold, modified for resale or used to manufacture commercial products without prior written approval from Creative Biolabs.

Send Inquiry

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Go to compare

Go to compare